Description

Technical Specifications

Item Parameter
Model GUD36W/A-D(U)
Performance Unit
Cooling Capacity 36000 Btu/h
Heating Capacity 36000 Btu/h
Power Supply 208/230V/1Ph/60Hz
Sound Pressure Level 52 (45-56) dB(A)
Energy Efficiency Unit
SEER 18
EER 11
HSPF 10
Electrical Data Unit
Minimum – Maximum Voltage 187-253 V
Control Voltage 24 V
Rated Current Cooling 14.5 A
Rated Current Heating 15 A
MCA 26.5 A
MOP 40 A
Dimension/Weight Unit
External Dimensions (HxWxD) 940×457×820/ (37x18x32-3/10) mm/inch
Net Weight 94.71/209 kg/lbs
Gross Weight 106.95/236 kg/lbs
Refrigerant Piping
Gas Pipe 19/(3/4) m/ft
Liquid Pipe 9.5/(3/8) m/ft
Standard Pipe Length 7.62/25 m/ft
Max refrigerant pipe length between Indoor and Outdoor (m) 30.48/100 m/ft
Max vertical height difference between Indoor and Outdoor (m) 15.24/ 50 m/ft
Other
Connection Method Flare/Screw
Refrigerant Type R410A
Precharge Refrigerant 3.4/123 kg/oz
Operation temperature for cooling -20 ~ 51/-5 ~ 125 C/°F
Operation temperature for heating -30 ~ 30/-22 ~ 86 C/°F